Description
Digital Earth Leakage Relay, 96x96mm, Panel Mount, 300mA to 30A, Class 2FS: Elmeasure iELR 300
- True RMS measurement
- Clearance and creepage distance meets UL 61010 safety standard
- Intelligent Protection – trip time is inversely proportional to fault current
- Field programmable trip current and trip time through front panel keys with password protection
- Continuous leakage current display (Programmable) – Leakage current is continuously displayed to enhance the user to understand of the quality of the Electrical network / Machine/troubleshooting online. This can be disabled through setup if required
- Continuous display of trip leakage current (Programmable) – In case of tripping, iELR captures and displays the tripped current with 4 Digits resolution, which helps the user to analyze and correct the problem. This can be disabled through setup if required
- Continuous scrolling display for set current and set time
- Manual test and reset keys l RS485 communication option
- Auto Configuration through communication
- Reset through communication in trip condition
- Protects control panels and switchboards from flame leakage
- Protects motors/transformers/feeders/generators etc., from earth leakage
- Hazardous and sensitive industries like oil refineries/pulp industries / electrical distribution etc. can be protected
- Complete protection for control engineering and mining industry
Advantages
- The microcontroller-based design provides a higher technological advantage
- Peak detection and value display help in the analysis and corrective action
- Password protection for security against mishandling
- Current sensitivity wider range 30mA – 3A and 300mA to 30A no limitations on set current (30mA to 30A coming soon)
- Programmable trip time 30ms – 30s with a wider choice to suit different industry
- Selection through soft keys (No DIP switches) provides better IP protection and longer life
- Continuous earth leakage value display helps online loss analysis (Programmable)
- Intelligent tripping based on T 1/A gives faster and more reliable protection
- Auto scrolling of trip information and peak fault current provides better analysis
Technical Specifications
Specification | iELR200
Din-Rail Mount |
iELR300
Panel Mount |
Display: | 4 Digit 4 Digit Input Current: 30mA to 3A or 300mA to 30A (30mA – 30A coming soon) | |
Trip Current: | Programmable | |
Tripping time: | 100 mS – 30 sec. | |
Contact Rating: | 2Amps @ 240V AC / 24V DC | |
Accuracy: | Class 5.0 FS (Default), Optional Class 2.0 FS | |
Auxiliary Supply: | 80 – 300V AC/DC, 4VA Max. | |
CBCT: | Round, Rectangular | |
Core Balance: | CT type: Tape wound limited round size, option for the epoxy coated and plastic version. | |
Communication: | Parity: Odd, Even, None (Preferred Even) | |
RS485 Interface: | Baud rate: 4800 bps to 38400 bps (Preferred 9600 bps) | |
(Optional) Isolation: | 2000 volts AC isolation for 1 minute between communication and other circuits. | |
Torque: | 1 N-m for Panel Mount, 0.2 N-m for DIN-rail | |
Wire Gauge: | 11 AWG |
Product Variants