Automatic Changeover with Current Limiter, 32A Single Phase Relay Based ACCL with Display, 4DIN, With RS485: Elmeasure iACCL M400

5,133.00

Elmeasure iACCl M400: Automatic Changeover with Current Limiter, 32A Single Phase Relay Based ACCL with Display, 4DIN, with RS485

  • Improved convenience of automatic source changeover.
  • Protection of equipment from hazardous power surges.
  • Rugged design for maximum performance and reliability.
  • Microcontroller based automatic source changeover with neutral isolation
  • Intelligent re-connection once trip has occurred due to either overvoltage or overload
  • Optional iACCL with Prepaid Metering feature can be given for DG side
  • Individual phase overload monitoring in 3 phase ACCL & overvoltage protection for DG
  • Power supply can be restored from sleep mode through MCB/Manual provision/ Mobile APP

Review and select the right model from the Product Catalog: Elmeasure ACCL

Description

Description

Automatic Changeover with Current Limiter, 32A Single Phase Relay Based ACCL with Display, 4DIN with RS485: Elmeasure iACCL M400
  • Microprocessor based ACCL with current limiter.
  • Intelligent tripping: inverse curve (Higher the overload, faster the trip)
  • Inbuilt display of A, V, F, Wh, kWh
  • Under/over voltage protection for EB and DG (M300)
  • Single phase contactor based ACCL with off-load switching.
  • On site field programmable features in single phase ACCL through configurator (ACCl 400 & 400C)
  • Conformity standard as per IEC 60947-6-1
  • Wide range of operational voltage (180-270) VAC
  • Optional prepaid billing feature for DG (RS-485) with software
  • More than 20000 operations
  • Display of overload information for both EB and DG, along with phase indication.
  • Installation is done as DIN rail for single phase and surface mountable for 3-phase (Optional DIN rail for 3 phase up to 40A).
  • Eco friendly thermoplastic and fire-retardant enclosure.
  • More than 20000 operations.
  • Reason for trip is displayed.
  • RS 485 communication. (Optional)
  • Protection against neutral current flow beyond threshold.
ACCL Models & Variants
ACCL Type Model Description
Single Phase ACCL without Display, 4DIN,Relay Based ACCL 400 32A Single Phase ACCL without Display, 4DIN,Relay Based
Single Phase ACCL without Display, 4DIN, Contactor Based iACCL 400C 32A Single Phase ACCL without Display, Contactor Based
Single Phase ACCL with Display, 4DIN, Relay Based iACCL M400 32A Single Phase ACCL with Display
iACCL M400 32A Single Phase ACCL with Display, RS485
3 Phase (EB) & Single Phase (DG) ACCL in 144x144mm construction, Contactor Based iACCL M330 32A Three Phase (EB) & Single Phase (DG) ACCL
iACCL M330 32A Three Phase (EB) & Single Phase (DG) ACCL, RS485
iACCL M330  40A Three Phase (EB) & Single Phase (DG) ACCL
iACCL M330 40A Three Phase (EB) & Single Phase (DG) ACCL, RS485
3 Phase ACCL, Contactor Based iACCL M300 32A Three Phase ACCL
iACCL M300 32A Three Phase ACCL, RS485
iACCL M300 40A Three Phase ACCL
iACCL M300 40A Three Phase ACCL, RS485
iACCL M300 63A Three Phase ACCL
iACCL M300 63A Three Phase ACCL, RS485
iACCL M300 80A Three Phase ACCL
iACCL M300 80A Three Phase ACCL, RS485
iACCL M300 100A Three Phase ACCL
iACCL M300 100A Three Phase ACCL, RS485
iACCL M300 125A Three Phase ACCL
iACCL M300 125A Three Phase ACCL, RS485
Additional information

Additional information

Brand

Elmeasure

Category Code

ELR300P91370000