Home » Shop » 3-Phase Digital Motor Protection Relay: SELEC MPR-341-2
SELEC MFM384-C-CE, LCD multifunction meter with RS485 communication for multiparameter monitoring including V, A, PF, Hz, W, Wh, VA, VAh, VARh
LCD Multifunction Meter-SELEC MFM384-C-D-CE-CL05-Plus Original price was: ₹9,990.00.Current price is: ₹8,991.00.
Back to products

3-Phase Digital Motor Protection Relay: SELEC MPR-341-2

2,964.00

Digital panel mount Motor Protection Relay (MPR), 2 x 1C/O, 85 to 270V AC / DC.

Digital MPR protects motors against Over and Under current, Current Assymentry, Dry Run as per NEMA Curve. It additionally gives protection against Earth’s Fault

 

 

Description

Description

3Ø Digital Motor Protection Relay: SELEC MPR-341-2

  • Monitors: Phase loss, Phase unbalance, Phase sequence, Overload trip current, Under / Over current in 3Ø motors.
  • Accuracy : 5% of set value.
  • 2 C/O output relay.
  • Auto / Remote test available.
  • MPCT range : 10A – 80A
  • Earth Fault Current Measurement with EFCT : 1A to 160A
  • Aux supply : 90 – 270V AC / DC

Brief Specifications

Measuring Parameter Monitors Over Load (As per NEMA Curve), Over Current, Under Current, Earth Fault, Lock Current, Current Asymmetry, Phase Sequence, Phase Failure
Electrical Connection 3Ø – 3W
Test / Reset Manual / Auto reset
No. of LED 2
Voltage Measuring Range 90V – 270V AC / DC
Earth Fault Current Measurement with EFCT 31A to 160A
Current Measuring Range 3A – 80A (via external MPCT)
Power Consumption 4VA (max)
Output Contact Trip 1 C/O Alarm 1 C/O (Programmable as Trip / Alarm),
Relay Rating NO 5A@250V AC / 28VDCNC 3A@250V AC / 28VDC
Accuracy Time ±5%+100msec Current 5% of IR(Rated Current),
Reset Auto / Manual
Functional Specifications Over Load NEMA class : Start with OFF then Curve 5, 10, 15, 20, 30,
Over Current Ranges : Start With OFF then 4A TO 480A of IR (Rated Current) Step Size : 1A
Time Setting Over Current Trip Time: 0 – 999sec,
Under Current Ranges : Start With OFF then 1A TO 79A,
Of IR (Rated Current) Step Size : 1A,
Under Current Trip Time: 0 – 999sec,
Current Asymmetry Ranges : Start With OFF then 1A TO (Ir-1)A,
Of IR (Rated Current) Step Size : 1A,
Current Asymmetry Trip time: 0 – 999sec,
Locked current / Stall current: (Ir+1)A to 60A(Default :20A),
(Ir+1)A to 240A(Default : 80A),
(Ir+1)A to 480A(Default: 160A) Step Size : 1A,
Locked Current Trip time: 0 – 999sec,
Earth Fault Ranges : Start With OFF then 1A TO 160A,
Step Size : 1%,
Earth Fault Trip time: 0 – 999sec,
Phase Loss trip time: Instantaneous,
Phase Reversal Trip time: Instantaneous
Auto Restart Attempt Time Frame 0 – 999sec for Current related parameter,
0 – 999sec for EFR
Mounting Panel Mount
Size 96 X 96mm
Additional information

Additional information

Brand